Page tree
Skip to end of metadata
Go to start of metadata
Description
When we select any module in the drop down, we will always land in the Investigation view at module level belonging to latest snapshot, though we have started with the historical/any snapshot of previous version from Quick Access View.
Observed in CAST AIP
Release
Yes/No
8.3.x (tick) 
8.2.x (tick) 
8.1.x (tick) 
8.0.x (tick) 
7.3.x(tick)
7.2.x(tick)
7.0.x(tick)
Observed on RDBMS
RDBMS
Yes/No
Oracle Server(tick)
Microsoft SQL Server(tick)
CSS2(tick)
CSS1(tick)
Step by Step Scenario
  1. From the quick access select any previous snapshot & access the Investigation Quality Model Drill down view
  2. From the left hand top drop down list, select any module

  3. This will land you in the Investigation Drill down view at the module level belonging to the latest snapshot and not the previous snapshot that you had selected in the Quick Access

Action Plan
  1. If you need the view of module belonging to any previous snapshot then as a workaround you need to suffix in the URL - &snapshot=<snapshot_id> as shown below :



Impact on Analysis Results and Dashboard

Analysis and Dashboard - N/A

Notes/comments
 This issue is planned to be fixed in 7.3.6
  • No labels