CMS Application - Execute - Fatal Error - Run Analysis only - Run Analysis only failed
*Purpose
The page will help you to troubleshoot the error message : Run Analysis Only failed when clicking Run Analysis only.


*Observed in CAST AIP
| Release | Yes/No |
|---|---|
| 8.3.x | ✅ |
*Observed on RDBMS
| RDBMS | Yes/No |
|---|---|
| CSS | ✅ |
Step by Step Scenario
- Package, deliver and set as current version the source code.
- In CAST Management Studio, at application level, in the Execute tab, click Run Analysis Only.
- The issue occurs
Action Plan
Open the CAST-MS log file.
Search for the generic error message Application - Run Analysis only failed
Check the content of the stack traces
Figure 2in the stack trace, check for the Technical / Functional message that is like (The technical / function message is in the stack trace but can be very far from the begining of the stack):

For the above example, the Technical / Functional message is : Source Server / 10288 - New: This application does not have a current version activated.
Following the Technical / Functional message, visit the below relevant page :
If the above pages do not help you to resolve the issue, contact CAST Technical Support and provide with with Relevant Input in order to reproduce the issue.