Description

This page will help you to troubleshoot fatal error that occurs when Saving the results of dataflow to the local database and the process throws the  error

ERR: 2021-05-19 16:42:12: User Input Data Flow Security analysis working file is missing for the application XXX. Ensure its jobs has been properly run after the User Input Data Flow Security analysis option has been activated.

Observed in CAST AIP
Release
Yes/No
8.3.x(tick)
Observed on RDBMS
RDBMS
Yes/No
CSS4(tick)
CSS3(tick)
CSS1(tick)
Action Plan

This message indicates that the file BuildAgent.datatransfer which is found in the subfolder of the J2EE/NET execution unit has not been created. This file is created by the Security Analyzer, hence this may indicate an issue when the J2EE/.NET data flow process was launched and before the file has been created.

  1. Check for any issue that occurred during CMS Snapshot Analysis - Run Data Flow Security Analysis - Run J2EE or NET Data Flow Security 
  2. If you do not find the information you are looking for or solution for your problem, on this page, contact CAST Technical Support  with the following Relevant input.

Relevant input

Notes