Purpose (problem description)

This page provides steps to troubleshoot the following Power Builder analysis error.

Cannot load XXX PowerBuilder pborc<version>.dll. The specified module could not be found

Observed in CAST AIP
Release
Yes/No
8.3.x(tick)
8.2.x(tick)
8.1.x(tick)
8.0.x(tick)
7.3.x(tick)
Observed on RDBMS
RDBMS
Yes/No
Oracle Server(tick)
Microsoft SQL Server(tick)
CSS3(tick)
CSS2(tick)
Step by Step scenario
  1. Use Delivery Manager Tool and deliver the source code.
  2. Run analysis.
Action Plan

Usually this error is raised if the Shared DLL Folder for Power Builder was not added to the PATH Environment Variable on the analysis machine.

  1. Add the PB path in Environment Variable path. It is :  <POWER BUILDER INSTALL_FOLDER>\srvsources\qualityassurance\STD\pb\Parsing\Shared_PB<version number>


Impact on Analysis Results and Dashboard

Impact of error : no Power Builder analysis