CAST AIP 8.2.8 contains all fixes from the following previous CAST AIP releases:

  • 7.3.0 - 7.3.11   
  • 8.0.0 - 8.0.5
  • 8.1.0 - 8.1.7
  • 8.2.0 - 8.2.7

The following table lists all bugs fixed in CAST AIP 8.2.8 and that are not already listed in the "Bug Fix Lists" of the above mentioned releases. There are 49 issues listed below. Note that the column "Internal ID" is used only as an internal reference ID.

 

Call IDTechnologyComponent/sFeaturesSituationSymptomsInternal ID
10045Oracle Forms Oracle ReportsCMS Snapshot/Analysis - Run Metrics Calculation When comparing the log of an Oracle Forms analysis step and the log from the Oracle Forms Metrics Assistant calculation step.There are more syntax errors in the Oracle Forms Metrics Assistant log (which are due to simple 'Select', 'Update' or 'CREATE OR REPLACE FUNCTION' statements) than there are in the Oracle Forms analysis log.SCRAIP-28729
10062N/ADelivery Manager Tool When using the CAST Delivery Manager Tool GUI.Some labels and options are poorly labelled.SCRAIP-28726
10103N/AApplication Analytics Dashboard (AAD) When looking at the CAST Application Analytics Dashboard.There are duplicate applications visible.SCRAIP-29856
10146JEE - JavaCMS Snapshot/Analysis When attempting to a run a JEE analysis.The analysis crashes with the error "Unexternalized exception - Message is 'access violation'."SCRAIP-28848
10176N/ACMS Snapshot/Analysis When attempting to generate a snapshot when using Oracle Server as host for the CAST AIP schemas.The snapshot fails with the error: 

ORA-01652: unable to extend temp segment by 128 in tablespace CTPTSD05 
 - ORA-06512: at "TEST_005.ADGC_DELTA_ALL_VIOL_REMOVED", line 107 
- ORA-06512: at line 1 java.sql.SQLException:ORA-01652: unable to extend temp segment by 128 in tablespace CTPTSD05
SCRAIP-29857
10217All TechnologiesCMS Snapshot/Analysis - Run Analyzer When an analysis is cancelled during the "run metric calculation" step and the analysis is then re-run again with the option "Continue last analysis".The subsequent analysis will skip the analysis that has already been completed, but it does not re-run the "run metric calculation" step (it should).SCRAIP-28974
10223JEE - JSPCMS Snapshot/Analysis When looking at the results of a JEE analysis including JSF taglib mapping files.JSF taglib mapping files are ignored, thus links are not created between *.xhtml files.SCRAIP-28952
10271ABAPCMS Snapshot/Analysis - Run Analyzer Attempting to run an ABAP analysis.The analysis fails with the error: SQL Error: ERROR: duplicate key value violates unique constraint "pk_objdsc". 

SCRAIP-29084
10287UniversalCMS Application - Reference Pattern Search String When attempting to run a UA analysis including a Reference Pattern search string.The Reference Pattern search string step takes a very long time to complete.SCRAIP-29018
10294JEE - JavaCMS Snapshot/Analysis - Run Analyzer When attempting to run a JEE analysis.The analysis fails with the error "Unable to process JEE analysis, error in project 'xxx'." SCRAIP-29081
10296N/AApplication Analytics Dashboard (AAD) When attempting to run a CAST Application Analytics Dashboar consolidation using the CLI.The process fails with the message "org.postgresql.util.PSQLException: ERROR: integer out of range".SCRAIP-29197
10297.NET - C#CMS Snapshot/Analysis - Compute Snapshot When attempting to generate a snapshot that has previously completed successfully. The snapshot now gets stuck on the procedure "ADGV_UPDATE_ANY_COST_STATUSES".SCRAIP-29097
10302.NET - C#Dataflow When running a .NET analysis.The Dataflow (User Input Security) step is taking a very long time to complete.SCRAIP-29261
10308JEE - JSPCMS Snapshot/Analysis When attempting to run a JEE analysis.The analysis fails with the error "Unable to process JEE analysis, error in project 'xxx'."SCRAIP-29117
10313N/AApplication Analytics Dashboard (AAD) When attempting to configure a "customexpression" tile in the CAST Application Analysis Dashboard.The tile functions but the title and description are merged together.SCRAIP-29170
10367JEE - JavaCMS Snapshot/Analysis When looking at the results of a JEE analysis which includes JSP files.Some JavaScript methods, variables and HTML events defined in the JSP file are duplicated, therefore increasing the number of dynamic links.SCRAIP-28963
10412N/AAnalysis Manager - Update CAST Knowledge Base When attempting to generate a snapshot.The snapshot generation process fails with the following errors in the CAST-MS log 
- relation inkb_dia_expensivepath 
- column "source_id" 
- relation "inkb_dataflowscope does not exist
SCRAIP-29265
10487Mainframe - CobolCAST Update Tool (CUT) When looking at the results of a post upgrade consistency snapshot after upgrading from a previous release of CAST AIP.Most of the Quality Rules shown a 100% variation in the CAST Engineering Dashboard > Investigation-quality model drilldown view.SCRAIP-29855
10638JEE - JavaCMS Snapshot/Analysis When looking at the log for a JEE analysis.The log contains many warning messages in the form "class 'xxx' is not visible - one dependency is missing" which have no impact on results and cannot be rectified. The warnings should be removed.SCRAIP-29585
10687N/AEnlighten When using CAST Enlighten.CAST Enlighten crashes while attempting to load a blank view during initial connection to the RDBMS.SCRAIP-29954
10958ABAPApplication Analytics Dashboard (AAD) When looking at the tile "Top 5 Critical Rules" in the CAST Application Analytics Dashboard.The Quality Rules in the tile do not appear to be ordered by Number of failed checks, as expected.SCRAIP-30101
7935Power BuilderCMS Snapshot/Analysis - Run Analyzer When looking at the log for a PowerBuilder analysis.There are several syntax warnings in the log. Some are legitimate and some are not and should be handled by the analyzer.SCRAIP-28784
8437Mainframe - CobolCMS Snapshot/Analysis When looking at the results of a Mainframe analysis (comparing Vn to Vn+1).The linker builds several inter-application links whereas it should not. 

SCRAIP-29868
8915N/ACAST Management Studio (CMS) When attempting to change the variable "CAST_CURRENT_USER_TEMP_PATH" in the CASTGlobalsettings.ini to alter the location in which the CAST-MSxx.log.txt file is stored.Changing the variable does nothing and the CAST-MSxx.log.txt file is still stored in the default location.SCRAIP-25807
8972N/ACAST Engineering Dashboard When using the CAST Engineering Dashboard to view results of the Quality Rule "Use only Hibernate API to access to the database" - 7510.The number of objects with violations is more than the number of failed checks.SCRAIP-25980
8993All TechnologiesApplication Analytics Dashboard (AAD) When looking at the CAST Application Analytics Dashboard: Application Fast Facts tile.The tiles show inconsistent data and is not being updated when a time period is selected.SCRAIP-26272
9094 CAST Update Tool (CUT) When looking at the DSS_HISTORY table post-upgrade.The DSS_HISTORY table is showing previous CAST AIP release number post upgrade. It should show the new CAST AIP release number.SCRAIP-26659
9145SQL - PL/SQLCAST Engineering Dashboard When looking at the results of the Quality Rule "Avoid SQL queries that no index can support - 7902".There are false positive violations of the Quality Rule due to CAST Database extractor not correctly handling IOT indexes.SCRAIP-29866
9295N/A  When attempting to install and run the CAST Analysis Automation API as a Windows Service.The installation fails because the batch files provided contain errors with regard to quote marks in file paths.SCRAIP-26958
9433;9832N/ACAST Engineering Dashboard When attempting to view TWRI data in either the CAST Engineering Dashboard or in the CAST Application Engineering Dashboard.The Transaction Level View in CED shows nothing, nor does the Transaction Investigation View in AED.SCRAIP-27094
9522JEE - JSPCMS Snapshot/Analysis When using the Text Replacement feature with the JEE Analyzer to correctly resolve some relative paths that are used in the source code.Even with Text Replacement, the expected links between JSP and JS files are still not found.SCRAIP-27096
9532Mainframe - CobolCMS Snapshot/Analysis - Check Modules When looking at the results of the Quality Rule "Variables defined in Working-Storage section must be initialized before to be read" (8034).A false positive result has been seen for this Quality Rule when the variable is initialised by a READ statement before being used by a WRITE statement.SCRAIP-28540
9536N/AApplication Analytics Dashboard (AAD) When looking at the tile "Top 5 Critical Rules" in the CAST Application Analytics Dashboard.The Quality Rules in the tile do not appear to be ordered by Number of failed checks, as expected.SCRAIP-29864
9565JEE - JSPCMS Snapshot/Analysis When looking at the results of a JEE analysis.No link is created from a JSP file that contains embedded Java code to the called Java methods.SCRAIP-27409
9571.NET - ASP.NETCMS Snapshot/Analysis When looking at the result of an analysis of an Application containing ASP/ASPX and Microsoft SQL Server database objects.Links are wrongly created between style properties in aspx/asp files and database tables that have the same name. For example, the following style property "background-color: #FFFFFF;" will cause the creation of links to database tables called background and color (if they exist).SCRAIP-29867
9593N/ACMS Snapshot/Analysis When attempting to run a JEE analysis.The analysis crashes during the 'computing dynamic links' step when analyzing files with cyclic class declaration.SCRAIP-29865
9607.NET - ASP.NETCMS Snapshot/Analysis - Run Analyzer When attempting run a .NET analysis.The analysis fails with the error "System.InvalidOperationException: Sequence contains more than one element".SCRAIP-27493
9652 CAST Engineering Dashboard 1. Create three modules M1 , M2 and M3 
2. Take V1 snapshot 
3. Delete M1 
4. Take V2 snapshot. 
5. Change snapshot version for V1.
Snapshot version is updated for M2 and M3 modules but not for module M1 (that is created in V1 and deleted in V2).SCRAIP-29863
9714.NET - ASP.NETCMS Snapshot/Analysis When looking at the results of a .NET/SQL Server analysis.Links have been incorrectly created from the JavaScript client site method in the .NET project to various Microsoft SQL Server tables.SCRAIP-27741
9723ABAPCAST Engineering Dashboard When looking at the results of the Quality Rule "Avoid missing WHEN OTHERS in CASE statements - 7518".False positive violations were returned due to the fact that the Quality Rule was not able to correctly handle situations where ELSE was used instead of WHEN OTHERS.SCRAIP-29861
9734Power BuilderCMS Snapshot/Analysis When looking at the logs of a PowerBuilder analysis.The log contains an error "Data cache : 'ObjPos' still contains data which may not have been flushed..."SCRAIP-29862
9765All TechnologiesServer Manager When attempting to connect to an RDBMS using CAST Server Manager and a custom extension is present on disk.The following error is displayed: "Incorrect module configuration : File c:\program files\cast\<version>\installscripts\common\diag\set_local.sql does not exist."SCRAIP-29860
9778JEE - JavaCAST Engineering Dashboard When looking at the results of the Quality Rule "Avoid String initialization with String object (created using the 'new' keyword)" - 7250.A false positive violation is identified for the Quality Rule where the String isn't initialized with a literal.SCRAIP-28667
9797JEE - JavaCMS Snapshot/Analysis When looking at the results of a JEE analysis.The logs show that not all .java files present in the delivered source code have been stored in the CAST Analysis Service schema, despite the fact that the files have been analyzed without error. Due to an issue saving files with the same name.SCRAIP-27996
9807Mainframe - CobolCMS Snapshot/Analysis When looking at the log file for a Mainframe Cobol analysis.The log file contains warning messages when a DD name contains an underscore. The analyzer thinks that the DD is in fact two separate items.SCRAIP-29859
9953JEE - JavaCMS Snapshot/Analysis When generating a snapshot on a JEE application.The snapshot takes a long time to complete with very poor performance on the procedure "DIAG_SCOPE_JAVAPPUB003".SCRAIP-29858
9972N/ATransaction Configuration Center (TCC) When using the CAST Transaction Configuration Center to look at a transaction in two projects: the transaction is identical in both projects (a.jsp file) and both projects have been analyzed in one Application.When one of the projects is dropped and a new snapshot is generated, two transactions incorrectly remain in the Analysis Service schema.SCRAIP-28628
9977Mainframe - JCLCMS Snapshot/Analysis When looking at the results of a Mainframe Cobol analysis and the source code uses a procedure parameter called JOB.When the analyzer encounters a procedure parameter that is called "JOB" it incorrectly considers it as a JOB card. This results in multiple issues, including incorrect Line of Code count (truncated source code) anda Computed FP value for the Transaction Function (JCL) as '0'.SCRAIP-28616
9985JEE - JavaCMS Snapshot/Analysis When looking at the results of a JEE analysis.Some hbm.xml files have their full path incorrectly set to a location in the LTSA folder, rather than in the source code deployment folder.SCRAIP-28533
  • No labels